{"product_id":"aenomed-vg-70","title":"Aenomed VG-70","description":"\u003cdiv class=\"markdown markdown-main-panel enable-updated-hr-color\" id=\"model-response-message-contentr_f47a652a7ca162dc\" aria-live=\"polite\" aria-busy=\"false\" dir=\"ltr\"\u003e\n\u003cp data-path-to-node=\"0\" id=\"p-rc_65994205e7ec481c-624\"\u003e\u003cspan class=\"citation-14749\"\u003eThe \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"4\"\u003e\u003cspan class=\"citation-14749\"\u003eAeonmed VG-70\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-14749 citation-end-14749\"\u003e is a premium, mobile critical care intensive care unit (ICU) ventilator engineered to deliver continuous respiratory support across all high-acuity clinical environments.\u003csup class=\"superscript\" data-turn-source-index=\"1\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-14748 citation-end-14748\"\u003eDesigned as a dual solution, the VG-70 balances full-featured invasive ventilation with highly flexible non-invasive mask therapy.\u003csup class=\"superscript\" data-turn-source-index=\"2\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-14747 citation-end-14747\"\u003eIt safely accommodates a broad patient spectrum, managing adult, pediatric, and infant patients during acute treatment phases, sub-acute care, and intra-hospital transport.\u003csup class=\"superscript\" data-turn-source-index=\"3\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"1\" id=\"p-rc_65994205e7ec481c-625\"\u003e\u003cspan class=\"citation-14746 citation-end-14746\"\u003eThe system is built around an ergonomic, detachable color touchscreen monitor paired with an integrated top alarm lamp that provides clear visual warnings from any direction.\u003csup class=\"superscript\" data-turn-source-index=\"4\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-14745 citation-end-14745\"\u003eThis design allows clinical teams to track respiratory waveforms, patient loops, and vital diagnostic data side-by-side for rapid bedside evaluation.\u003csup class=\"superscript\" data-turn-source-index=\"5\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"2\"\u003eKey Clinical Advantages\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-path-to-node=\"3,0,0\" id=\"p-rc_65994205e7ec481c-626\"\u003e\n\u003cspan class=\"citation-14744\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-14744\"\u003eInfrastructure-Independent Internal Turbine:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-14744 citation-end-14744\"\u003e Outfitted with an ultra-quiet internal turbine blower that compresses ambient air to generate precise breathing gas pressure.\u003csup class=\"superscript\" data-turn-source-index=\"6\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-14743 citation-end-14743\"\u003eThis eliminates the need for an external air compressor or a central wall gas infrastructure, securing outstanding mobility throughout the hospital.\u003csup class=\"superscript\" data-turn-source-index=\"7\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,1,0\" id=\"p-rc_65994205e7ec481c-627\"\u003e\n\u003cspan class=\"citation-14742\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-14742\"\u003eIntelligent Lung-Protective Strategies:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-14742 citation-end-14742\"\u003e Features advanced ventilation modes, including Pressure Regulated Volume Control and dual-level positive airway pressure modes.\u003csup class=\"superscript\" data-turn-source-index=\"8\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-14741 citation-end-14741\"\u003eThese modes automatically adapt to real-time changes in lung status, delivering the targeted breath volume using the lowest possible pressure to protect fragile tissue.\u003csup class=\"superscript\" data-turn-source-index=\"9\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,2,0\" id=\"p-rc_65994205e7ec481c-628\"\u003e\n\u003cspan class=\"citation-14740\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-14740\"\u003eComprehensive Patient Range Adaptability:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-14740 citation-end-14740\"\u003e Configured with a wide tidal volume delivery bracket.\u003csup class=\"superscript\" data-turn-source-index=\"10\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-14739 citation-end-14739\"\u003eIt supports specialized lower-volume boundaries and custom settings to safely accommodate pediatric patients starting from a small body weight.\u003csup class=\"superscript\" data-turn-source-index=\"11\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,3,0\" id=\"p-rc_65994205e7ec481c-629\"\u003e\n\u003cspan class=\"citation-14738\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-14738\"\u003eAutoclavable Integrated Exhalation Valve:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-14738 citation-end-14738\"\u003e Designed with a durable, metal-based heated exhalation valve assembly.\u003csup class=\"superscript\" data-turn-source-index=\"12\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-14737 citation-end-14737\"\u003eThe entire module can be easily detached and autoclaved between patient cases, promoting strict hospital infection control and reducing device turnaround times.\u003csup class=\"superscript\" data-turn-source-index=\"13\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,4,0\" id=\"p-rc_65994205e7ec481c-630\"\u003e\n\u003cspan class=\"citation-14736\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-14736\"\u003eNon-Consumable Flow Sensor Technology:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-14736 citation-end-14736\"\u003e Incorporates a high-precision, built-in flow sensor mechanism featuring a non-consumable design.\u003csup class=\"superscript\" data-turn-source-index=\"14\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-14735 citation-end-14735\"\u003eThis provides highly accurate flow measurement and breath triggering over extended operation periods without requiring routine replacement parts.\u003csup class=\"superscript\" data-turn-source-index=\"15\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,5,0\" id=\"p-rc_65994205e7ec481c-631\"\u003e\n\u003cspan class=\"citation-14734\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,5,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-14734\"\u003eAdvanced Visual Leakage Compensation:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-14734 citation-end-14734\"\u003e Outfitted with an automatic leak detection and adjustment system that compensates for gas loss during non-invasive mask therapy.\u003csup class=\"superscript\" data-turn-source-index=\"16\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-14733 citation-end-14733\"\u003eThis ensures precise volume delivery and prevents accidental pressure alarms, maintaining optimal patient comfort.\u003csup class=\"superscript\" data-turn-source-index=\"17\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,6,0\" id=\"p-rc_65994205e7ec481c-632\"\u003e\n\u003cspan class=\"citation-14732\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,6,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-14732\"\u003eComplete Lung Mechanics Monitoring:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-14732 citation-end-14732\"\u003e Tracks comprehensive lung diagnostics right on the main console, including dynamic compliance, airway resistance, intrinsic positive end-expiratory pressure, and work of breathing trends.\u003csup class=\"superscript\" data-turn-source-index=\"18\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,7,0\" id=\"p-rc_65994205e7ec481c-633\"\u003e\n\u003cspan class=\"citation-14731\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,7,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-14731\"\u003eAutomatic Tube Compensation (ATC):\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-14731 citation-end-14731\"\u003e Equipped with specialized software that calculates and continuously counteracts the physical resistance imposed by endotracheal or tracheostomy tubes, easing the patient's breathing effort during weaning.\u003csup class=\"superscript\" data-turn-source-index=\"19\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,8,0\" id=\"p-rc_65994205e7ec481c-634\"\u003e\n\u003cspan class=\"citation-14730\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,8,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-14730\"\u003eExtended Mobile Battery Power:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-14730 citation-end-14730\"\u003e Supported by an integrated high-capacity battery layout that can be expanded to supply hours of continuous, uninterrupted internal operational power.\u003csup class=\"superscript\" data-turn-source-index=\"20\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-14729 citation-end-14729\"\u003eThis makes the ventilator fully prepared for transport to surgical spaces or imaging suites.\u003csup class=\"superscript\" data-turn-source-index=\"21\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,9,0\" id=\"p-rc_65994205e7ec481c-635\"\u003e\n\u003cspan class=\"citation-14728\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,9,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-14728\"\u003eSmart Suction and Safety Procedures:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-14728 citation-end-14728\"\u003e Programmed with automated care routines, including a one-touch suction protocol that delivers high-concentration oxygen before and after airway clearing to safeguard the patient from sudden oxygen drops.\u003csup class=\"superscript\" data-turn-source-index=\"22\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:  Excellent - Imported Pre Owned\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Abdullah Surgical","offers":[{"title":"Default Title","offer_id":48430251835617,"sku":"VR2692017","price":1000000.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0833\/4465\/4561\/files\/224_ee1db5c5-fe85-475a-89cd-2c8c33116bd1.png?v=1780741585","url":"https:\/\/www.abdullahsurgical.store\/products\/aenomed-vg-70","provider":"Abdullah Surgical","version":"1.0","type":"link"}