{"product_id":"drager-evita-2-dura","title":"Drager Evita 2 Dura","description":"\u003cdiv class=\"markdown markdown-main-panel enable-updated-hr-color\" id=\"model-response-message-contentr_b892ea28b6e0347d\" aria-live=\"polite\" aria-busy=\"false\" dir=\"ltr\"\u003e\n\u003cp data-path-to-node=\"0\" id=\"p-rc_e9c7309a36b73c29-404\"\u003e\u003cspan class=\"citation-8629\"\u003eThe \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"4\"\u003e\u003cspan class=\"citation-8629\"\u003eDräger Evita 2 Dura\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-8629 citation-end-8629\"\u003e is a highly reliable, medical-grade critical care ventilator engineered to deliver continuous respiratory support across intensive care units and high-dependency care environments.\u003csup class=\"superscript\" data-turn-source-index=\"1\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-8628 citation-end-8628\"\u003eRecognized as a clinical workhorse for everyday hospital routines, the Evita 2 Dura balances conventional mechanical ventilation modes with a modular upgrade path and patient-friendly software options.\u003csup class=\"superscript\" data-turn-source-index=\"2\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"1\" id=\"p-rc_e9c7309a36b73c29-405\"\u003e\u003cspan class=\"citation-8627 citation-end-8627\"\u003eThe front control panel is built around a clear screen layout that displays real-time breathing curves and vital monitored parameters side-by-side.\u003csup class=\"superscript\" data-turn-source-index=\"3\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-8626 citation-end-8626\"\u003eUtilizing a straightforward control knob and a three-step selection system, the console gives clinical teams excellent visibility while reducing the operational complexity of everyday patient monitoring.\u003csup class=\"superscript\" data-turn-source-index=\"4\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"3\"\u003eKey Clinical Advantages\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-8625\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"4,0,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-8625\"\u003eUniversal Patient Range Adaptability:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-8625 citation-end-8625\"\u003e Configured to accommodate a wide variety of clinical cases, safely managing adult and pediatric patients.\u003csup class=\"superscript\" data-turn-source-index=\"5\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-8624 citation-end-8624\"\u003eWith the addition of a specialized low-flow monitoring option, the unit can be upgraded to support fragile neonatal and infant patients.\u003csup class=\"superscript\" data-turn-source-index=\"6\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-8623\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"4,1,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-8623\"\u003eRoom to Breathe Spontaneous Design:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-8623 citation-end-8623\"\u003e Built with an advanced open breathing system that actively encourages independent patient breathing efforts at any time during the mechanical breath cycle.\u003csup class=\"superscript\" data-turn-source-index=\"7\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-8622 citation-end-8622\"\u003eThis strategy improves patient comfort and speeds up the overall recovery process.\u003csup class=\"superscript\" data-turn-source-index=\"8\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-8621\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-8621\"\u003eAutoFlow Volume Compensation:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-8621 citation-end-8621\"\u003e Features intelligent software for volume-controlled modes that automatically regulates the inspiratory gas flow.\u003csup class=\"superscript\" data-turn-source-index=\"9\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-8620 citation-end-8620\"\u003eThis allows the system to achieve the target breath volume while maintaining the lowest possible pressure levels inside the patient's lungs.\u003csup class=\"superscript\" data-turn-source-index=\"10\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-8619\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"4,3,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-8619\"\u003eBIPAP and Advanced Weaning Modes:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-8619 citation-end-8619\"\u003e Outfitted with Biphasic Positive Airway Pressure capabilities, serving as a universal ventilation and weaning mode that helps smoothly transition patients toward independent respiration.\u003csup class=\"superscript\" data-turn-source-index=\"11\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-8618\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"4,4,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-8618\"\u003eAutomatic Tube Compensation Option:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-8618 citation-end-8618\"\u003e Supports an advanced clinical feature that calculates and offsets the internal mechanical resistance imposed by a tracheal tube.\u003csup class=\"superscript\" data-turn-source-index=\"12\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-8617 citation-end-8617\"\u003eThis helps lower the patient's work of breathing, simulating a virtual extubation state.\u003csup class=\"superscript\" data-turn-source-index=\"13\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-8616\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"4,5,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-8616\"\u003eTwo-In-One Non-Invasive Ventilation:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-8616 citation-end-8616\"\u003e Capable of executing both conventional invasive intubation support and non-invasive mask ventilation therapies on a single device.\u003csup class=\"superscript\" data-turn-source-index=\"14\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-8615 citation-end-8615\"\u003eThis dual capability helps reduce the clinical re-intubation rate and expands hospital utility.\u003csup class=\"superscript\" data-turn-source-index=\"15\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-8614\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"4,6,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-8614\"\u003eHighly Customizable Control Screen:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-8614 citation-end-8614\"\u003e Displays real-time respiratory curves alongside six vital monitored data values.\u003csup class=\"superscript\" data-turn-source-index=\"16\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-8613 citation-end-8613\"\u003eClinical staff can rearrange the screen configuration to highlight the most critical metrics for their specific intensive care ward.\u003csup class=\"superscript\" data-turn-source-index=\"17\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-8612\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"4,7,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-8612\"\u003eSimplified Routine Maintenance Procedures:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-8612 citation-end-8612\"\u003e Designed to reduce clinical downtime via daily automated sensor calibrations and an easy-access exhalation valve assembly that can be swapped or serviced in a matter of seconds.\u003csup class=\"superscript\" data-turn-source-index=\"18\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"citation-8611\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"4,8,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-8611\"\u003eStreamlined Start-Up Configurations:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-8611 citation-end-8611\"\u003e Allows hospital technicians to preset custom default parameters and initial breath settings that align perfectly with their facility's specific intensive care protocols, speeding up point-of-care patient connection.\u003csup class=\"superscript\" data-turn-source-index=\"19\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:  Excellent - Imported Pre Owned\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Abdullah Surgical","offers":[{"title":"Default Title","offer_id":48430251016417,"sku":"VR2692009","price":350000.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0833\/4465\/4561\/files\/216_f8beade4-ff2b-4d1d-a149-af09f23f90de.png?v=1780740334","url":"https:\/\/www.abdullahsurgical.store\/products\/drager-evita-2-dura","provider":"Abdullah Surgical","version":"1.0","type":"link"}