{"product_id":"drager-evita-4","title":"Drager Evita 4","description":"\u003cdiv class=\"markdown markdown-main-panel enable-updated-hr-color\" id=\"model-response-message-contentr_167c90dc106d5b83\" aria-live=\"polite\" aria-busy=\"false\" dir=\"ltr\"\u003e\n\u003cp data-path-to-node=\"0\" id=\"p-rc_d3c8d0ff634d45a4-369\"\u003e\u003cspan class=\"citation-7874\"\u003eThe \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"4\"\u003e\u003cspan class=\"citation-7874\"\u003eDräger Evita 4\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-7874 citation-end-7874\"\u003e is a premium, high-performance critical care ventilator engineered to deliver reliable long-term respiratory support across the entire patient spectrum, safely managing neonatal, pediatric, and adult cases.\u003csup class=\"superscript\" data-turn-source-index=\"1\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-7873 citation-end-7873\"\u003eDesigned to thrive in high-acuity intensive care environments, the Evita 4 balances conventional pneumatic volume and pressure therapies with unique, open-breathing software modalities.\u003csup class=\"superscript\" data-turn-source-index=\"2\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"1\" id=\"p-rc_d3c8d0ff634d45a4-370\"\u003e\u003cspan class=\"citation-7872 citation-end-7872\"\u003eFeaturing a functional touchscreen interface paired with direct-access keys and a central rotary control knob, the system provides clinical teams with clear viewing capabilities.\u003csup class=\"superscript\" data-turn-source-index=\"3\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-7871 citation-end-7871\"\u003eIt displays customizable arrangements of real-time curves, respiratory loops, and advanced data trends, focusing on operational efficiency and fast setup at the patient’s bedside.\u003csup class=\"superscript\" data-turn-source-index=\"4\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"2\"\u003eKey Clinical Advantages\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-path-to-node=\"3,0,0\" id=\"p-rc_d3c8d0ff634d45a4-371\"\u003e\n\u003cspan class=\"citation-7870\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-7870\"\u003eFull Patient Range and Premature Support:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-7870 citation-end-7870\"\u003e Outfitted to manage a wide patient weight bracket, starting from adult cases down to neonates.\u003csup class=\"superscript\" data-turn-source-index=\"5\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-7869 citation-end-7869\"\u003eFacilities can also deploy a specialized NeoFlow setting to supply precise, low-volume flow triggering and leakage adaptation for premature infants.\u003csup class=\"superscript\" data-turn-source-index=\"6\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,1,0\" id=\"p-rc_d3c8d0ff634d45a4-372\"\u003e\n\u003cspan class=\"citation-7868\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-7868\"\u003eAutoFlow Adaptive Volume Delivery:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-7868 citation-end-7868\"\u003e Features an intelligent software enhancement for volume-controlled modes that automatically regulates the inspiratory flow.\u003csup class=\"superscript\" data-turn-source-index=\"7\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-7867 citation-end-7867\"\u003eThis allows the ventilator to maintain the targeted breath volume using the lowest possible airway pressure, adapting directly to changes in lung compliance.\u003csup class=\"superscript\" data-turn-source-index=\"8\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,2,0\" id=\"p-rc_d3c8d0ff634d45a4-373\"\u003e\n\u003cspan class=\"citation-7866\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-7866\"\u003eBIPAP Open Breathing Architecture:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-7866 citation-end-7866\"\u003e Built with an advanced open breathing circuit concept that allows completely unrestricted spontaneous breathing during any phase of the mechanical breath cycle, significantly lowering patient discomfort and promoting synchrony.\u003csup class=\"superscript\" data-turn-source-index=\"9\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,3,0\" id=\"p-rc_d3c8d0ff634d45a4-374\"\u003e\n\u003cspan class=\"citation-7865\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-7865\"\u003eAirway Pressure Release Ventilation (APRV):\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-7865 citation-end-7865\"\u003e Programmed with an independent APRV mode that supports spontaneous breathing on two distinct pressure levels for extended time frames, stabilizing lung volumes and optimizing oxygenation for severe respiratory distress cases.\u003csup class=\"superscript\" data-turn-source-index=\"10\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,4,0\" id=\"p-rc_d3c8d0ff634d45a4-375\"\u003e\n\u003cspan class=\"citation-7864\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-7864\"\u003eAutomatic Tube Compensation (ATC):\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-7864 citation-end-7864\"\u003e Equipped with specialized, optional software that calculates and continuously offsets the physical breathing resistance caused by endotracheal or tracheostomy tubes, reducing the patient's overall breathing effort during weaning.\u003csup class=\"superscript\" data-turn-source-index=\"11\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,5,0\" id=\"p-rc_d3c8d0ff634d45a4-376\"\u003e\n\u003cspan class=\"citation-7863\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,5,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-7863\"\u003eMandatory Minute Volume (MMV) Weaning:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-7863 citation-end-7863\"\u003e Utilizes a smart interactive mode that ensures the patient always receives a preset minute volume.\u003csup class=\"superscript\" data-turn-source-index=\"12\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-7862 citation-end-7862\"\u003eThe system continuously checks spontaneous breathing levels and automatically supplies mandatory breaths only if the patient's own effort drops below the target threshold.\u003csup class=\"superscript\" data-turn-source-index=\"13\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,6,0\" id=\"p-rc_d3c8d0ff634d45a4-377\"\u003e\n\u003cspan class=\"citation-7861\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,6,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-7861\"\u003eAdvanced Non-Invasive Mask Therapy (NIV):\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-7861 citation-end-7861\"\u003e Offers high-performance mask ventilation choices across all operating modes, paired with advanced leakage compensation software to prevent accidental alarms while maintaining correct breath volumes during high-leak scenarios.\u003csup class=\"superscript\" data-turn-source-index=\"14\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,7,0\" id=\"p-rc_d3c8d0ff634d45a4-378\"\u003e\n\u003cspan class=\"citation-7860\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,7,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-7860\"\u003eIntegrated Expiratory Block and Sensor Lifespan:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-7860 citation-end-7860\"\u003e Designed with an optimized expiration block housing and patient heating setup that actively reduces liquid condensation inside the circuit line, protecting internal electronics and extending the structural lifespan of the flow sensor.\u003csup class=\"superscript\" data-turn-source-index=\"15\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,8,0\" id=\"p-rc_d3c8d0ff634d45a4-379\"\u003e\n\u003cspan class=\"citation-7859\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,8,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-7859\"\u003eOn-Board Diagnostics and Occlusion Tracking:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-7859 citation-end-7859\"\u003e Tracks essential safety parameters right on the main console, including automatic airway pressure monitoring, breathing gas temperature, and rapid diagnostic checks like occlusion pressure trends to evaluate spontaneous drive.\u003csup class=\"superscript\" data-turn-source-index=\"16\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,9,0\" id=\"p-rc_d3c8d0ff634d45a4-380\"\u003e\n\u003cspan class=\"citation-7858\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,9,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-7858\"\u003eReliable Emergency and Transport Features:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-7858 citation-end-7858\"\u003e Supported by an internal backup battery module to sustain continuous mechanical ventilation during sudden facility electrical power drops or when transferring patients between different hospital wards.\u003csup class=\"superscript\" data-turn-source-index=\"17\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:  Excellent - Imported Pre Owned\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Abdullah Surgical","offers":[{"title":"Default Title","offer_id":48430250950881,"sku":"VR2692008","price":550000.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0833\/4465\/4561\/files\/219_80a35958-9eef-4bfd-bd0b-2f46319d408c.png?v=1780740331","url":"https:\/\/www.abdullahsurgical.store\/products\/drager-evita-4","provider":"Abdullah Surgical","version":"1.0","type":"link"}