{"product_id":"maquet-servo-300","title":"Maquet Servo 300","description":"\u003cdiv class=\"markdown markdown-main-panel enable-updated-hr-color\" id=\"model-response-message-contentr_eda7bc17e98fd80a\" aria-live=\"polite\" aria-busy=\"false\" dir=\"ltr\"\u003e\n\u003cp data-path-to-node=\"0\" id=\"p-rc_c3cff34ca1530300-335\"\u003e\u003cspan class=\"citation-7127\"\u003eThe \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"4\"\u003e\u003cspan class=\"citation-7127\"\u003eMaquet Siemens Servo 300\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-7127 citation-end-7127\"\u003e is a highly reliable, classic critical care ventilator engineered to deliver precise respiratory support across all patient categories, from fragile neonates and pediatric cases to adult patients.\u003csup class=\"superscript\" data-turn-source-index=\"1\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-7126 citation-end-7126\"\u003eKnown as a foundational workhorse in intensive care mechanical ventilation, this system balances robust mechanical gas delivery with an adaptable design that allows it to serve multiple intensive care environments.\u003csup class=\"superscript\" data-turn-source-index=\"2\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"1\" id=\"p-rc_c3cff34ca1530300-336\"\u003e\u003cspan class=\"citation-7125 citation-end-7125\"\u003eThe system consists of a distinct Control Unit with manual adjustments and a Patient Unit featuring integrated transducers.\u003csup class=\"superscript\" data-turn-source-index=\"3\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-7124 citation-end-7124\"\u003eIt provides clinical teams with a straightforward, practical front-panel layout that displays vital pressures and volumes on clear indicator lamps, focusing on high operational reliability and easy bedside management.\u003csup class=\"superscript\" data-turn-source-index=\"4\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"2\"\u003eKey Clinical Advantages\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-path-to-node=\"3,0,0\" id=\"p-rc_c3cff34ca1530300-337\"\u003e\n\u003cspan class=\"citation-7123\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-7123\"\u003eUniversal Patient Range Capability:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-7123 citation-end-7123\"\u003e Features a quick patient selection knob that allows clinical staff to instantly adjust preset flow and volume boundaries.\u003csup class=\"superscript\" data-turn-source-index=\"5\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-7122 citation-end-7122\"\u003eThis design allows a single unit to smoothly transition between neonatal, pediatric, and adult settings.\u003csup class=\"superscript\" data-turn-source-index=\"6\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,1,0\" id=\"p-rc_c3cff34ca1530300-338\"\u003e\n\u003cspan class=\"citation-7121\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-7121\"\u003ePressure Regulated Volume Control (PRVC):\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-7121 citation-end-7121\"\u003e Outfitted with advanced PRVC technology to deliver a target volume using the lowest possible airway pressure.\u003csup class=\"superscript\" data-turn-source-index=\"7\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-7120 citation-end-7120\"\u003eThe system continuously adapts to changes in the patient's lung compliance, reducing the risk of pressure-related lung injury.\u003csup class=\"superscript\" data-turn-source-index=\"8\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,2,0\" id=\"p-rc_c3cff34ca1530300-339\"\u003e\n\u003cspan class=\"citation-7119\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-7119\"\u003eAutomode Smart Transition Software:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-7119 citation-end-7119\"\u003e Includes an intelligent weaning feature that continuously checks for patient activity.\u003csup class=\"superscript\" data-turn-source-index=\"9\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-7118 citation-end-7118\"\u003eAfter consecutive spontaneous breaths, the system smoothly shifts from controlled to supported ventilation, and automatically reverts to controlled mode if the patient stops breathing.\u003csup class=\"superscript\" data-turn-source-index=\"10\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,3,0\" id=\"p-rc_c3cff34ca1530300-340\"\u003e\n\u003cspan class=\"citation-7117\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-7117\"\u003eUltra-Sensitive Flow and Pressure Triggering:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-7117 citation-end-7117\"\u003e Utilizes high-precision internal transducers to recognize even the weakest spontaneous breathing efforts.\u003csup class=\"superscript\" data-turn-source-index=\"11\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-7116 citation-end-7116\"\u003eThis rapid valve response minimizes the patient's work of breathing and lowers discomfort during active phases.\u003csup class=\"superscript\" data-turn-source-index=\"12\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,4,0\" id=\"p-rc_c3cff34ca1530300-341\"\u003e\n\u003cspan class=\"citation-7115\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-7115\"\u003eVolume Support (VS) Interactive Mode:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-7115 citation-end-7115\"\u003e Outfitted with a patient-regulated mode that supplies a set volume while allowing the patient to control the respiratory rate and timing, maximizing comfort during the weaning process.\u003csup class=\"superscript\" data-turn-source-index=\"13\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,5,0\" id=\"p-rc_c3cff34ca1530300-342\"\u003e\n\u003cspan class=\"citation-7114\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,5,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-7114\"\u003eOptional High-Resolution Screen Module:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-7114 citation-end-7114\"\u003e Can be expanded with a dedicated secondary display screen that adds graphical capabilities.\u003csup class=\"superscript\" data-turn-source-index=\"14\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-7113 citation-end-7113\"\u003eThis provides real-time waveforms, respiratory loops, and historical data trends spanning up to twenty-four hours.\u003csup class=\"superscript\" data-turn-source-index=\"15\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,6,0\" id=\"p-rc_c3cff34ca1530300-343\"\u003e\n\u003cspan class=\"citation-7112\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,6,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-7112\"\u003eIntegrated Air Filtration and Gas Mixing:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-7112 citation-end-7112\"\u003e Built with high-efficiency internal gas modules that filter incoming air and oxygen supply.\u003csup class=\"superscript\" data-turn-source-index=\"16\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-7111 citation-end-7111\"\u003eThis guarantees clean, bacteria-free gas delivery while precisely blending oxygen concentrations.\u003csup class=\"superscript\" data-turn-source-index=\"17\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,7,0\" id=\"p-rc_c3cff34ca1530300-344\"\u003e\n\u003cspan class=\"citation-7110\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,7,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-7110\"\u003eDedicated Oxygen Suction Function:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-7110 citation-end-7110\"\u003e Programmed with a one-touch suction protocol button that temporarily supplies high-concentration oxygen before and after airway clearing procedures to protect against oxygen drops.\u003csup class=\"superscript\" data-turn-source-index=\"18\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,8,0\" id=\"p-rc_c3cff34ca1530300-345\"\u003e\n\u003cspan class=\"citation-7109\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,8,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-7109\"\u003eAutomatic Emergency Battery Protection:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-7109 citation-end-7109\"\u003e Outfitted with an internal emergency battery backup system that instantly assumes operation in the event of a facility electrical power loss, maintaining continuous patient ventilation without interruption.\u003csup class=\"superscript\" data-turn-source-index=\"19\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:  Excellent - Imported Pre Owned\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Abdullah Surgical","offers":[{"title":"Default Title","offer_id":48430250819809,"sku":"VR2692006","price":350000.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0833\/4465\/4561\/files\/214_d9610f9f-8db3-4080-955b-8c4d4a443e49.png?v=1780738222","url":"https:\/\/www.abdullahsurgical.store\/products\/maquet-servo-300","provider":"Abdullah Surgical","version":"1.0","type":"link"}