{"product_id":"maquet-servo-i","title":"Maquet Servo I","description":"\u003cdiv class=\"markdown markdown-main-panel enable-updated-hr-color\" id=\"model-response-message-contentr_4a7aab148b7e4d9b\" aria-live=\"polite\" aria-busy=\"false\" dir=\"ltr\"\u003e\n\u003cp data-path-to-node=\"0\" id=\"p-rc_d883a212147c2a2c-300\"\u003e\u003cspan class=\"citation-6408\"\u003eThe \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"4\"\u003e\u003cspan class=\"citation-6408\"\u003eMaquet Servo-i\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-6408 citation-end-6408\"\u003e is a premium, critical care intensive care unit (ICU) ventilator engineered to deliver exceptional respiratory support across all patient categories, from fragile neonates and pediatric patients to adult patients.\u003csup class=\"superscript\" data-turn-source-index=\"1\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-6407 citation-end-6407\"\u003ePositioned as a highly adaptable and modular workstation, the Servo-i balances conventional pneumatic positive-pressure therapy with cutting-edge, patient-controlled breathing technologies.\u003csup class=\"superscript\" data-turn-source-index=\"2\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"1\" id=\"p-rc_d883a212147c2a2c-301\"\u003e\u003cspan class=\"citation-6406 citation-end-6406\"\u003eFeaturing a large, high-resolution user interface with responsive touch controls and direct-access knobs, the system provides clinical teams with outstanding visibility.\u003csup class=\"superscript\" data-turn-source-index=\"3\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-6405 citation-end-6405\"\u003eIt displays clean, un-cluttered real-time waveforms, lung mechanics loops, and diagnostic trend data, focusing on fast intraoperative setup and streamlined adjustments at the bedside.\u003csup class=\"superscript\" data-turn-source-index=\"4\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"2\"\u003eKey Clinical Advantages\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-path-to-node=\"3,0,0\" id=\"p-rc_d883a212147c2a2c-302\"\u003e\n\u003cspan class=\"citation-6404\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-6404\"\u003eAll-Inclusive Patient Platform:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-6404 citation-end-6404\"\u003e Outfitted with a highly precise gas delivery system that spans a single, upgradable architecture, allowing a single unit to smoothly transition between the neonatal intensive care unit (NICU) and adult intensive care environments.\u003csup class=\"superscript\" data-turn-source-index=\"5\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,1,0\" id=\"p-rc_d883a212147c2a2c-303\"\u003e\n\u003cspan class=\"citation-6403\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-6403\"\u003eNeurally Adjusted Ventilatory Assist (NAVA):\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-6403 citation-end-6403\"\u003e Supports revolutionary technology that utilizes the patient's own electrical diaphragm signals to control the ventilator.\u003csup class=\"superscript\" data-turn-source-index=\"6\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-6402 citation-end-6402\"\u003eThis unique feature bypasses traditional pneumatic sensors to eliminate lag time and ensure total patient-ventilator harmony.\u003csup class=\"superscript\" data-turn-source-index=\"7\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,2,0\" id=\"p-rc_d883a212147c2a2c-304\"\u003e\n\u003cspan class=\"citation-6401\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-6401\"\u003eAutomode Smooth Weaning Technology:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-6401 citation-end-6401\"\u003e Features an interactive breathing mode that automatically transitions between controlled ventilation and supported ventilation based on real-time patient effort.\u003csup class=\"superscript\" data-turn-source-index=\"8\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-6400 citation-end-6400\"\u003eThis minimizes manual staff adjustments and supports a smoother, safer weaning process.\u003csup class=\"superscript\" data-turn-source-index=\"9\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,3,0\" id=\"p-rc_d883a212147c2a2c-305\"\u003e\n\u003cspan class=\"citation-6399\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-6399\"\u003ePressure Regulated Volume Control (PRVC):\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-6399 citation-end-6399\"\u003e Combines the safety of volume targeting with the comfort of pressure-controlled delivery.\u003csup class=\"superscript\" data-turn-source-index=\"10\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-6398 citation-end-6398\"\u003eThe system continuously measures lung compliance and automatically supplies the targeted breath volume using the lowest possible airway pressure.\u003csup class=\"superscript\" data-turn-source-index=\"11\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,4,0\" id=\"p-rc_d883a212147c2a2c-306\"\u003e\n\u003cspan class=\"citation-6397\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-6397\"\u003eAdvanced Open Lung Tool Diagnostics:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-6397 citation-end-6397\"\u003e Integrated with on-screen visual tools that assist clinicians in safely executing lung recruitment strategies.\u003csup class=\"superscript\" data-turn-source-index=\"12\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-6396 citation-end-6396\"\u003eIt tracks dynamic compliance metrics on screen to help determine the most effective positive end-expiratory pressure (PEEP) settings.\u003csup class=\"superscript\" data-turn-source-index=\"13\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,5,0\" id=\"p-rc_d883a212147c2a2c-307\"\u003e\n\u003cspan class=\"citation-6395\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,5,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-6395\"\u003eLeak-Compensated Non-Invasive Ventilation (NIV):\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-6395 citation-end-6395\"\u003e Outfitted with high-performance non-invasive software that dynamically detects and adjusts for mask or interface leaks.\u003csup class=\"superscript\" data-turn-source-index=\"14\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-6394 citation-end-6394\"\u003eThis ensures stable pressure delivery, precise triggering, and accurate volume monitoring even during mask ventilation.\u003csup class=\"superscript\" data-turn-source-index=\"15\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,6,0\" id=\"p-rc_d883a212147c2a2c-308\"\u003e\n\u003cspan class=\"citation-6393\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,6,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-6393\"\u003eHeliox Therapeutic Gas Delivery:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-6393 citation-end-6393\"\u003e Built to safely blend and manage Helium-Oxygen gas mixtures across both invasive and non-invasive modes.\u003csup class=\"superscript\" data-turn-source-index=\"16\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-6392 citation-end-6392\"\u003eThis therapeutic gas option reduces gas turbulence inside the airways, effectively lowering the patient's work of breathing.\u003csup class=\"superscript\" data-turn-source-index=\"17\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,7,0\" id=\"p-rc_d883a212147c2a2c-309\"\u003e\n\u003cspan class=\"citation-6391\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,7,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-6391\"\u003eOne-Piece Interchangeable Expiratory Cassette:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-6391 citation-end-6391\"\u003e Designed with a removable, fully cleanable expiratory cassette system.\u003csup class=\"superscript\" data-turn-source-index=\"18\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-6390 citation-end-6390\"\u003eThis architecture allows the ventilator to be instantly refreshed with a clean cassette between cases, maximizing machine availability and ensuring strict hospital infection control.\u003csup class=\"superscript\" data-turn-source-index=\"19\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,8,0\" id=\"p-rc_d883a212147c2a2c-310\"\u003e\n\u003cspan class=\"citation-6389\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,8,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-6389\"\u003eUltra-Sensitive Sensor Feedback Control:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-6389 citation-end-6389\"\u003e Utilizes advanced flow and pressure triggering mechanisms that analyze patient airway demands hundreds of times per second.\u003csup class=\"superscript\" data-turn-source-index=\"20\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-6388 citation-end-6388\"\u003eThe fast valve response time provides instant flow to eliminate breathing discomfort and reduce patient fatigue.\u003csup class=\"superscript\" data-turn-source-index=\"21\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,9,0\" id=\"p-rc_d883a212147c2a2c-311\"\u003e\n\u003cspan class=\"citation-6387\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,9,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-6387\"\u003eMobile Intra-Hospital Transport Capability:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-6387 citation-end-6387\"\u003e Mounted on a durable, low-profile rolling trolley cart equipped with hot-swappable plug-in battery modules.\u003csup class=\"superscript\" data-turn-source-index=\"22\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-6386 citation-end-6386\"\u003eThis design secures uninterrupted, high-quality treatment during patient transfers between intensive care beds, imaging suites, and operating rooms.\u003csup class=\"superscript\" data-turn-source-index=\"23\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:  Excellent - Imported Pre Owned\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Abdullah Surgical","offers":[{"title":"Default Title","offer_id":48430250787041,"sku":"VR2692005","price":600000.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0833\/4465\/4561\/files\/213_efa72ac5-74f2-4c70-a719-d9e7914b4a93.png?v=1780740235","url":"https:\/\/www.abdullahsurgical.store\/products\/maquet-servo-i","provider":"Abdullah Surgical","version":"1.0","type":"link"}