{"product_id":"viasys-carefusion-avea","title":"Viasys Carefusion Avea","description":"\u003cdiv class=\"markdown markdown-main-panel enable-updated-hr-color\" id=\"model-response-message-contentr_6fb07a255c049beb\" aria-live=\"polite\" aria-busy=\"false\" dir=\"ltr\"\u003e\n\u003cp data-path-to-node=\"0\" id=\"p-rc_34778ab909ebd1a6-185\"\u003e\u003cspan class=\"citation-3099\"\u003eThe \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"4\"\u003e\u003cspan class=\"citation-3099\"\u003eViasys CareFusion AVEA\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-3099 citation-end-3099\"\u003e is a premium, comprehensive critical care ventilator system engineered to deliver invasive and non-invasive mechanical ventilation across the entire patient spectrum, from neonatal and pediatric to adult patients.\u003csup class=\"superscript\" data-turn-source-index=\"1\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-3098 citation-end-3098\"\u003ePositioned as a versatile, high-acuity workstation for intensive care units (ICUs) and intra-hospital transport, the AVEA balances sophisticated physiological monitoring with precise gas delivery.\u003csup class=\"superscript\" data-turn-source-index=\"2\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"1\" id=\"p-rc_34778ab909ebd1a6-186\"\u003e\u003cspan class=\"citation-3097 citation-end-3097\"\u003eFeaturing a large, 12.1-inch color touchscreen interface module that displays real-time graphics, waveforms, and loops, the AVEA offers exceptional visibility.\u003csup class=\"superscript\" data-turn-source-index=\"3\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-3096 citation-end-3096\"\u003eIt presents clinical teams with an intuitive, highly customizable layout of monitored respiratory parameters, focusing on streamlined bedside operation and rapid clinical decision-making.\u003csup class=\"superscript\" data-turn-source-index=\"4\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"2\"\u003eKey Clinical Advantages\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-path-to-node=\"3,0,0\" id=\"p-rc_34778ab909ebd1a6-187\"\u003e\n\u003cspan class=\"citation-3095\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-3095\"\u003eFull Patient Spectrum Capability:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-3095 citation-end-3095\"\u003e Engineered with a highly precise gas delivery system capable of supplying accurate tidal volumes ranging from 2 mL for fragile neonates up to 2.5 L for adult patients.\u003csup class=\"superscript\" data-turn-source-index=\"5\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,1,0\" id=\"p-rc_34778ab909ebd1a6-188\"\u003e\n\u003cspan class=\"citation-3094\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-3094\"\u003eExclusive BiCore Pulmonary Monitoring:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-3094 citation-end-3094\"\u003e Integrated with advanced BiCore technology to provide real-time tracking of transpulmonary, esophageal, and tracheal pressures.\u003csup class=\"superscript\" data-turn-source-index=\"6\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-3093 citation-end-3093\"\u003eThis allows clinicians to measure the exact work of breathing and optimize PEEP titration directly at the bedside.\u003csup class=\"superscript\" data-turn-source-index=\"7\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,2,0\" id=\"p-rc_34778ab909ebd1a6-189\"\u003e\n\u003cspan class=\"citation-3092\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-3092\"\u003eComprehensive Volumetric Capnography:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-3092 citation-end-3092\"\u003e Offers advanced, volume-based capnography configurations that supply breath-by-breath \u003csup class=\"superscript\" data-turn-source-index=\"8\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"CO_2\" data-index-in-node=\"124\"\u003e$CO_2$\u003c\/span\u003e\u003cspan class=\"citation-3091 citation-end-3091\"\u003e data.\u003csup class=\"superscript\" data-turn-source-index=\"9\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-3090 citation-end-3090\"\u003eIt tracks anatomic dead space, alveolar minute ventilation, and \u003csup class=\"superscript\" data-turn-source-index=\"10\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"V_d\/V_t\" data-index-in-node=\"199\"\u003e$V_d\/V_t$\u003c\/span\u003e\u003cspan class=\"citation-3089 citation-end-3089\"\u003e ratios to aid in quick clinical reactions during critical situations.\u003csup class=\"superscript\" data-turn-source-index=\"11\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,3,0\" id=\"p-rc_34778ab909ebd1a6-190\"\u003e\n\u003cspan class=\"citation-3088\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-3088\"\u003eAutomated Assessment Maneuvers:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-3088 citation-end-3088\"\u003e Programmed to execute routine diagnostic tests in the background, providing automated measurements for MIP\/NIF, AutoPEEP, and Slow Flow (\u003csup class=\"superscript\" data-turn-source-index=\"12\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"P_{flex}\" data-index-in-node=\"169\"\u003e$P_{flex}$\u003c\/span\u003e\u003cspan class=\"citation-3087 citation-end-3087\"\u003e) maneuvers to calculate low- and high-inflection points.\u003csup class=\"superscript\" data-turn-source-index=\"13\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,4,0\" id=\"p-rc_34778ab909ebd1a6-191\"\u003e\n\u003cspan class=\"citation-3086\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-3086\"\u003eActive Exhalation Valve Technology:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-3086 citation-end-3086\"\u003e Utilizes a software-driven, active exhalation valve system that actively promotes ventilator synchrony, minimizes the patient's work of breathing, and maximizes comfort during complex ventilation cycles.\u003csup class=\"superscript\" data-turn-source-index=\"14\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,5,0\" id=\"p-rc_34778ab909ebd1a6-192\"\u003e\n\u003cspan class=\"citation-3085\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,5,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-3085\"\u003eAdvanced Heliox Blending Integration:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-3085 citation-end-3085\"\u003e Features a patented, internal Heliox blending system that automatically compensates for helium\/oxygen gas mixtures across all concentrations without requiring manual recalibration or changing hardware.\u003csup class=\"superscript\" data-turn-source-index=\"15\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,6,0\" id=\"p-rc_34778ab909ebd1a6-193\"\u003e\n\u003cspan class=\"citation-3084\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,6,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-3084\"\u003eIndependent On-Board Compressor:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-3084 citation-end-3084\"\u003e Outfitted with an internal, low-maintenance scroll compressor that allows the ventilator to transition smoothly from the ICU wall gas supply to mobile operations.\u003csup class=\"superscript\" data-turn-source-index=\"16\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli data-path-to-node=\"3,7,0\" id=\"p-rc_34778ab909ebd1a6-194\"\u003e\n\u003cspan class=\"citation-3083\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,7,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-3083\"\u003eDurable Transport Battery Power:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-3083 citation-end-3083\"\u003e Built to support an internal and optional external battery configuration, providing up to two hours of continuous, independent operation of both the ventilator and the compressor during intra-hospital transport to CT scans or diagnostic suites.\u003csup class=\"superscript\" data-turn-source-index=\"17\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:  Excellent - Imported Pre Owned\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Abdullah Surgical","offers":[{"title":"Default Title","offer_id":48430250459361,"sku":"VR2692001","price":375000.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0833\/4465\/4561\/files\/209_f68600b7-a88e-417b-ba31-e7ed62d91abb.png?v=1780739905","url":"https:\/\/www.abdullahsurgical.store\/products\/viasys-carefusion-avea","provider":"Abdullah Surgical","version":"1.0","type":"link"}